The role of network ion fan


1, ion electrostatic eliminator In addition to static principle: the formation of air ions, the role of static power and static electricity.

2, to allow air ionization of the way:

A, strong electric field under the conditions of air corona ionization, resulting in positive and negative ions;

B, A-ray and β-ray action of air molecules to make it an air ion; C, high-energy radiation (X-ray) role of air separation base ionization;

Characteristics of air ions

1, the air ion is different from the solution ions, it requires a certain amount of energy to be generated, and usually in the form of molecular groups;

2, air ions in the natural environment also exists, but the concentration is very low;

3, in the clean air which the air ion life in a few seconds to a few minutes;

4, positive and negative ions together will be neutral with each other;

Several issues need to be considered in the use of ion electrostatic eliminator

1, the role of distance to consider two factors:

A, the closer the distance to eliminate static electricity faster;

B, different types of ion static eliminator effective distance is different.

2, the strong electric field ionization way of the ion electrostatic eliminator discharge needle is the most easy to aging and damage to the parts, regular cleaning and maintenance to ensure that the equipment is effective.

3, to eliminate static speed: considerations - dissipation rate, generally measured with CPM 1000V-100V dissipation rate;

4, ion balance: ion imbalance will make the role of the region to bring the table turtle, it must be controlled. Ion imbalance occurs only in the ionization of corona ionization equipment;

5, other considerations: different types of ionization equipment for different objects.



Network ion fan

Features:

1) large air volume, wide range of ion wind, can be placed on the table can also be suspended installation.

2) rapid elimination of static electricity, ion balance voltage of 0V ± 10V, can continuously adjust the wind speed, with heating function.

3) with ion needle cleaning brush, ion indicator light.

Technical Parameters:

Operating voltage

110V / 60HZ, 220V / 50HZ

Current consumption

3.0A / 1.5A

Operating temperature

0-50 ° C

Airflow area

60cmx120cm

Dimensions

450mm (L) x220mm (W) x190mm (H)

weight

8KG

Air volume

70-120CFM

Ion balance

0V ± 10V